The UE shall be able to identify new intra-frequency cells and perform RSRP and RSRQ measurements of identified intra-frequency cells without an explicit intra-frequency neighbour list containing physical layer cell identities.
An intra frequency cell is considered to be detectable according to RSRP, RSRP Ês/Iot, SCH_RP and SCH Ês/Iot as defined below for a corresponding Band.
- RSRP in dBm > -124 dBm for Bands 1, 4, 6, 10, 11, 18, 19, 21, 33, 34, 35, 36, 37, 38, 39, 40 and RSRP Ês/Iot -4 dB,
- RSRP in dBm -123 dBm for Band 9 and RSRP Ês/Iot -4 dB,
- RSRP in dBm -122 dBm for Bands 2, 5, 7 and RSRP Ês/Iot -4 dB,
- RSRP in dBm -121 dBm for Bands 3, 8, 12, 13, 14, 17, 20 and RSRP Ês/Iot -4 dB,
The UE shall not consider a E-UTRA neighbour cell in cell reselection, if it is indicated as not allowed in the measurement control system information of the serving cell.